MetricsHub
MetricsHub Community Connectors 1.0.07
Back to the list of connectors[1]
lm_sensors
Description
This connector enables the monitoring of environment sensors on Linux, through the sensors command.
community[2] hardware[3] linux[4]
Source[5]
Target
Typical platform: Any system
Operating system: Linux
Prerequisites
Leverages: lm_sensors
Technology and protocols: Command Lines
This connector requires advanced privileges on the managed host for the commands below:
/usr/sbin/dmidecode
/usr/bin/sensors
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the commands listed above.
Sample of /etc/sudoers to allow the above commands to be run as root by the metricshub account:
metricshub ALL=(root) NOPASSWD: /usr/sbin/dmidecode
metricshub ALL=(root) NOPASSWD: /usr/bin/sensors
Examples
CLI
metricshub HOSTNAME -t linux -c +lmsensors --ssh -u USER --sudo-command-list /usr/sbin/dmidecode,/usr/bin/sensors
metricshub.yaml
resourceGroups:
<RESOURCE_GROUP>:
resources:
<HOSTNAME-ID>:
attributes:
host.name: <HOSTNAME> # Change with actual host name
host.type: linux
connectors: [ +lmsensors ] # Optional, to load only this connector
protocols:
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using metricshub-encrypt
useSudo: true
useSudoCommands: [ "/usr/sbin/dmidecode", "/usr/bin/sensors" ]
Connector Activation Criteria
The lm_sensors connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Linux
- The command below succeeds on the monitored host
- Command:
/usr/bin/sensors -h
- Output contains:
Usage: sensors
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes |
---|---|---|
enclosure |
|
|
fan |
|
|
temperature |
|
|
voltage |
|
|